top of page

FREDRICK A., AGE 76

SUMMARY

Fredrick was what many would consider a 'high risk' patient for a full mouth teeth restoration using implants. Having type 2 diabetes and previous radiation treatment for cancer, he had been turned away by other offices for restorative oral treatment.  We were able to successfully restore his smile with the 3 on 6™ and at a 2-year follow up Fredrick is healthier and happier and his smile is also strong and healthy.

CONSULTATION NOTES

Pt on time for apt w/Dr. Roberts 

Pt unhappy w/smile, pt interested in poss restoring U & L arch w/ 3 on 6. 

Took pano & CT Scan 

Dr. Roberts examined/ went over tx w/pt

Pt a great candidate for U & L 3 on 6. 

Treatment Planned: Tx- U & L immediate dentures, U & L 3 on 6

Nv; Impressions for U & L immediate dentures. (Take B pics)

MEDICAL HISTORY

type 2 diabetes, artificial knee, sinus trouble, hay fever, cold sores, high cholesterol, had prostate cancer, had radiation treatment, currently no prescription medications, non-smoker

SPECIAL CONSIDERATIONS

Duis aute irure dolor in reprehenderit in voluptate velit esse cillum dolore eu fugiat nulla pariatur. Excepteur sint occaecat cupidatat non proident, sunt in culpa qui officia deserunt mollit anim id est laborum.

PROCEDURE NOTES

  • U&L 3 on 6 Ext, Imp, BG - Neodent w/ Dr. Robert

  • pt present for apt. rmh- nsf. ioe/eoe-wnl.

  • pt signed consent forms

  • Offered pt 1 tab ibuprofen 800mg-

  • had pt rinse w/ chlorhexidine mouth rinse

  • Placed topical benzocaine

  • Dr. Roberts admin - 14 carpules 2% Vivacaine

  • Simply Extracted all upper & Lower Teeth

  • pulled back tissue on #3,6,7,10,11,14,19,222,23,26,27,30 expanded holes using Neodent replace tapered system

 

Neodent implants

#3 140.629 Size 4,3x13,mm

#6 140.684 Size 3.5x16,mm

#7 140.629 Size 4,3x16,mm

#10 140. 684 Size 3.5x16,mm

#11 140. 629 Size 4,3x16,mm

#14 140. 628 Size 3.4x13,mm

#19 140. 688 Size 4.3x10.mm

#22 140. 684 Size 3,5x6,mm

#23 140. 683 Size 3,5x13,mm

#26 140. 684 Size 3,5x16,mm

#27 140. 629 Size 4,3x16,mm

#30 140.648 Size 4,3x10,mm

 

  • used torque wrench to 35.

  • placed bone grafting material mineralized Maxxeus cortical/cancellous cadaver bone (5.0.cc cadavar bone )REF# DH050 SN# 180195-080- LOT# 81-3871

FOLLOW UP

Duis aute irure dolor in reprehenderit in voluptate velit esse cillum dolore eu fugiat nulla pariatur. Excepteur sint occaecat cupidatat non proident, sunt in culpa qui officia deserunt mollit anim id est laborum.

bottom of page